The FAOPS 2020 congress archive preserves the scientific record of the Tokyo meeting, including its focus on perinatal medicine. Although the congress was cancelled in April 2020 because of COVID-19 and international travel disruption, its programme and educational stories remain relevant to Australian clinicians working with newborn infants and their families.
Umbilical venous catheters (UVCs) and umbilical arterial catheters (UAC) provide short-term access for essential treatment. UVCs support central venous access, fluid administration and some exchange transfusion procedures, while UACs allow continuous arterial blood pressure monitoring and blood sampling. Umbilical catheter complications include infection, thrombosis, occlusion, malposition, vascular injury and catheter-related bloodstream infection. Learn more about 骨盤底筋と体幹安定性の関連.
In Australia, prevention and management depend on sterile technique, accurate tip confirmation, continuous surveillance and early removal when access is no longer required. Neonatal intensive care units, or NICUs, often include neonatologists, junior doctors, neonatal nurses, vascular access nurses, pharmacists and allied-health staff. Their shared protocols should reflect current unit policy, Australian neonatal guidance and the needs of families facing prolonged or geographically complex care.
Both devices are temporary instruments with immediate benefits, but their risks rise when placement, maintenance or removal is delayed.
| Feature | Umbilical venous catheter | Umbilical arterial catheter |
|---|---|---|
| Principal role | Central venous access, fluids, medication and sometimes exchange transfusion | Continuous arterial monitoring and blood sampling |
| Typical tip target | Inferior vena cava–right atrial junction or another position accepted by local protocol | Descending aorta above the diaphragm or a low position above the pelvis, depending on protocol |
| Major concerns | Thrombosis, perforation, infection and necrotising enterocolitis if positioned or used inappropriately | Arterial spasm, thrombosis, bleeding and vascular or spinal injury |
| Ongoing priorities | Daily necessity review, secure access, careful maintenance and prompt removal | Accurate monitoring, continuous assessment of perfusion and prompt removal |
The choice is driven by the clinical indication, gestational age, available access and condition of the umbilical vessels. A UVC may be appropriate when a newborn requires central access, while a UAC is usually selected for arterial pressure monitoring or repeated samples. Neither should remain simply because insertion is convenient.
Preterm and growth-restricted infants are particularly vulnerable. Their vessels are fragile, their defences against infection are immature and conditions such as thrombocytopenia can complicate vascular access. Every catheter therefore requires a clear purpose, an anticipated duration and a daily decision about whether it still earns its place.
Insertion should be treated as a sterile procedure. Australian NICUs commonly use a dedicated insertion trolley, a second trained person and maximal sterile barrier precautions, including gowns, masks, a cap, gloves and an appropriate sterile drape. The operator should confirm the vessel, calculate the required length and document the final position without relying on the external fixation mark alone.
Skin preparation must suit neonatal skin and the product’s approved instructions. Depending on unit policy, a newborn’s skin and umbilical stump may be prepared with alcohol, chlorhexidine or another approved antiseptic. The area should be allowed to dry, and antiseptic must not pool beneath the stump because chemical injury can cause tissue damage. Cleaning should not be confused with antisepsis, and the umbilical stump should be assessed for bleeding, discharge or loosening.
Maintenance depends on consistent hand hygiene, disinfection of access hubs, closed connectors and an intact dressing. The insertion site, catheter markings, connections and infusion delivery need regular inspection. A daily “line necessity” review should compare the clinical indication with the least invasive available access. Documentation must also survive transfers: babies travelling through Sydney or other major centres may move with NETS, while Queensland Neonatal Retrieval Service covers a similarly dispersed network. Handover should include catheter length, tip position, dressing condition, infusates and known complications.
Catheter-related infection may present as temperature instability, apnoea, bradycardia, lethargy, poor feeding, colour change or increasing respiratory need. The umbilical site can look normal, particularly in a preterm infant, and a positive blood culture is not required before treating suspected neonatal sepsis. Escalation should be immediate when the newborn’s clinical condition changes, rather than waiting for routine review.
Maternal illness can shape neonatal risk before the first catheter is inserted. Chorioamnionitis, maternal infection and systemic inflammation require close newborn observation and may influence the empirical antibiotic pathway. The FAOPS resource on maternal sepsis antibiotic therapy is useful context for teams coordinating obstetric and neonatal responses.
Mechanical complications often produce practical warning signs. Resistance during aspiration, unexplained resistance to infusion, bleeding around the stump, swelling of an extremity, reduced perfusion, new oxygen requirement or an arrhythmia may indicate occlusion, malposition or vascular injury. Infusion should be stopped and the line assessed rather than forced, with senior neonatal and radiology input obtained when the position or clinical consequence is uncertain.
A radiograph remains a common method for confirming catheter position after insertion, while ultrasound and targeted echocardiography can provide additional information about the tip and surrounding structures. The whole catheter course should be reviewed, not merely the point where it appears to end. Local procedures should define when imaging is required, who reviews it and how urgently the line may be used in an emergency.
A UVC placed too high can cause arrhythmia, cardiac tamponade or hepatic injury, while a low position increases thrombosis and necrotising enterocolitis concerns. A UAC may be positioned above the diaphragm or lower in the aorta, but each approach has its own hazards. Securement, dressings and body movement can also permit migration, so repeat imaging may be needed after a difficult procedure or unexplained change in the baby’s condition.
Placental disease affects how safely these infants tolerate vascular access. The FAOPS review of preeclampsia pathophysiology and treatments explains the association with fetal growth restriction, and affected newborns may also have thrombocytopenia or compromised perfusion. These features do not change sterile insertion standards, but they make careful tip confirmation, pressure monitoring and early removal more important.
Suspected catheter-related bloodstream infection requires rapid assessment. Peripheral and catheter blood cultures should be obtained when feasible without delaying treatment, followed by empiric antibiotics according to the neonatal sepsis pathway. Source control may require catheter removal, particularly with fungal infection, persistent bacteraemia, tunnelling or another strong indicator. Alternative access should be planned before removing a clinically essential line.
Thrombosis can present with swelling, pain, reduced limb perfusion, persistent thrombocytopenia or an unexpected change in blood pressure. Ultrasound with Doppler may help define the problem, while haematology input is valuable when anticoagulation is considered. Evidence in newborns remains limited, and routine pharmacological prophylaxis is not a substitute for accurate placement and daily line review. An obstructed catheter should never be flushed forcefully; permitted aspiration or irrigation must follow the unit protocol.
Suspected malposition or extravasation requires the infusion to be stopped immediately. Residual fluid may be aspirated when safe, followed by imaging and review by neonatal, radiology and vascular access teams. An inadvertently positioned arterial catheter used as a venous line can cause severe arrhythmia or tissue injury, so suspicious readings require prompt investigation rather than simple adjustment of the infusion pump.
Necrotising enterocolitis, abdominal distension, feeding intolerance, major bleeding or signs of limb ischaemia demand urgent neonatal review and a renewed assessment of catheter necessity. Removal should be based on the balance of continuing indications, infection, thrombosis and available alternative access. The decision, discussion with the family and reasons for delayed removal should be clearly documented and communicated at every handover.
Families should receive clear explanations about why a line is present, how it is protected and what may happen if it becomes infected, blocked or dislodged. In centres caring for Aboriginal and Torres Strait Islander families, cultural safety, accessible language and interpreter support can make these discussions more effective. A mother’s recovery also deserves attention after a traumatic birth or prolonged neonatal admission; a Japanese peer-reviewed discussion of pelvic floor stability may support physiotherapy teams considering conservative rehabilitation alongside local care pathways.
Teams can act at the next neonatal handover: standardise the insertion checklist, assign responsibility for each catheter, confirm tip position and dressing condition, review every suspected infection and remove lines that are no longer required. Public tertiary hospitals and private maternity units should use the same transfer documentation so that line history, cultures and unresolved concerns follow the infant.
Safe umbilical access is built through repeated prevention, early recognition and decisive removal. Every sterile insertion, careful line review and infection prevented protects a newborn from harms that can last well beyond the hospital stay.